|
|
(8 intermediate revisions by 5 users not shown) |
Line 20: |
Line 20: |
| *Overall health percentage | | *Overall health percentage |
| *Damage of each basic type | | *Damage of each basic type |
| *If patient has cellular damage or not
| |
| *Blood Type and level | | *Blood Type and level |
| *Medical ID | | *Medical ID |
Line 47: |
Line 46: |
| |strategy = Use it on your patient and see readings | | |strategy = Use it on your patient and see readings |
| |description = Has all of the features of a normal health analyzer, but it can see quite a bit more. | | |description = Has all of the features of a normal health analyzer, but it can see quite a bit more. |
| * It can display the cellular damage level
| |
| * It can display the stamina level | | * It can display the stamina level |
| * It can display the radiation level | | * It can display the radiation level |
Line 55: |
Line 53: |
| * It can display more advanced virus statistics (transmission levels, severity levels, etc.) | | * It can display more advanced virus statistics (transmission levels, severity levels, etc.) |
| * It can display blood levels | | * It can display blood levels |
| * It can display cellular damage
| |
| * It can display genetic stability | | * It can display genetic stability |
| }} | | }} |
Line 367: |
Line 364: |
| |usedfor = Transporting pills | | |usedfor = Transporting pills |
| |strategy = Put pills inside, take pills out when needed | | |strategy = Put pills inside, take pills out when needed |
| |description = It's an airtight container for storing medication. | | |description = It's an airtight container for storing medication. Can store up to seven pills or patches, and fits in your pocket. |
| }} | | }} |
|
| |
|
Line 516: |
Line 513: |
| |usedfor = Putting the patient asleep | | |usedfor = Putting the patient asleep |
| |strategy = See below | | |strategy = See below |
| |description = A tank filled with Nitrous Oxide for keeping the patient unconscious during surgery to prevent him/her from <s>escaping</s> feeling pain. | | |description = A tank filled with Nitrous Oxide for keeping the patient unconscious during surgery to prevent them from <s>escaping</s> feeling pain. |
| '''How to set internals:''' | | '''How to set internals:''' |
| * To set internals and make your patient sleep you need to first remove any item from their back. Once done you need to put a breath mask on them and then put the anesthetic tank onto their back. Once it is on their back you can put them on internals by clicking "set internals" on the same menu you used to put the tank on their back. Once done your patient should fall asleep. Remember to use a proper anesthetic mixture, as pure N2O will suffocate the patient. | | * To set internals and make your patient sleep you need to first remove any item from their back. Once done you need to put a breath mask on them and then put the anesthetic tank onto their back. Once it is on their back you can put them on internals by clicking "set internals" on the same menu you used to put the tank on their back. Once done your patient should fall asleep. Remember to use a proper anesthetic mixture, as pure N2O will suffocate the patient. |
Line 530: |
Line 527: |
| |usedfor = Amputation | | |usedfor = Amputation |
| |strategy = See below | | |strategy = See below |
| |description = A type of heavy duty surgical shears used for achieving a clean separation between limb and patient. Keeping the patient still is imperative to be able to secure and align the shears. It dismembers a limb(or tail) after a delay (15 seconds by default).<br> | | |description = A type of heavy duty surgical shears used for achieving a clean separation between limb and patient. Keeping the patient still is imperative to be able to secure and align the shears. It dismembers a limb (or tail) after a delay (15 seconds by default).<br> |
|
| |
|
| * If the patient is incapacitated, critted, dead, unconscious, paralyzed, staminacritted, etc. the amputation speed is cut in half. | | * If the patient is incapacitated, critted, dead, unconscious, paralyzed, staminacritted, etc. the time required to amputate something is cut in half. |
| * If the patient is [[Status_Effects#Jitteriness|jittery]] the time needed is multiplied by 1.5. | | * If the patient is [[Status_Effects#Jitteriness|jittery]] the time required to amputate something is multiplied by 1.5. |
| }} | | }} |
|
| |
|
Line 543: |
Line 540: |
| |image = Blood_filter.png | | |image = Blood_filter.png |
| |foundin = [[Operating Theatre]] | | |foundin = [[Operating Theatre]] |
| |usedfor = [[Surgery#Blood_Filter|Filter Blood surgery]] | | |usedfor = [[Surgery#Filter_Blood|Filter Blood surgery]] |
| |description = A tool used when performing the [[Surgery#Blood_Filter|blood filter surgery]]. | | |description = A tool used when performing the [[Surgery#Filter_Blood|filter blood surgery]]. |
| }} | | }} |
|
| |
|
Line 840: |
Line 837: |
| |usedfor = Healing critical (or not critical) patients and genetic damage | | |usedfor = Healing critical (or not critical) patients and genetic damage |
| |strategy = Set the cryo up and put people in. Eject them after they've healed up | | |strategy = Set the cryo up and put people in. Eject them after they've healed up |
| |description = These high-tech devices can bring crew members back from the brink of death. The station starts with two, but they have to be set up first. It automatically stabilizes people in [[Guide_to_medicine#Critically_Wounded|critical condition]], and will safely lower a patient's body temperature to levels at which [[Cryoxadone]], usually mixed with [[Mannitol]], is effective. These chemicals will heal all damage types, and are the only way to fix cellular damage caused by slime feeding. | | |description = These high-tech devices can bring crew members back from the brink of death. The station starts with two, but they have to be set up first. The aircan that spawns at cryo starts with oxygen/n2o to make sure that the patient is sleeping for cryoxadone to take efffect. It automatically stabilizes people in [[Guide_to_medicine#Critically_Wounded|critical condition]], and will safely lower a patient's body temperature to levels at which [[Cryoxadone]], usually mixed with [[Mannitol]], is effective. Cryoxadone heals all damage types while Mannitol heals the brain. |
|
| |
|
| You can quickly operate the Cryogenics Tube without opening the menu with a few shortcuts. ALT + left click will toggle the doors, and CTRL + left click will toggle the power. | | You can quickly operate the Cryogenics Tube without opening the menu with a few shortcuts. ALT + left click will toggle the doors, and CTRL + left click will toggle the power. |
Line 882: |
Line 879: |
| |strategy = Get to bodies fast enough and jump-start their heart | | |strategy = Get to bodies fast enough and jump-start their heart |
| |description = A smaller version of the defibrillator, found in the [[Chief Medical Officer|CMO's]] office. Fits on the belt slot, rather than the back slot. Can bring patients out of death and into crit if they have only been dead a short time (only a few minutes). Does brain damage, though, and doesn't work if patients are not [[Ghost|in their bodies]] or if they are heavily damaged. Runs on power cells. Can be emagged for a heavy stun and some burn damage. | | |description = A smaller version of the defibrillator, found in the [[Chief Medical Officer|CMO's]] office. Fits on the belt slot, rather than the back slot. Can bring patients out of death and into crit if they have only been dead a short time (only a few minutes). Does brain damage, though, and doesn't work if patients are not [[Ghost|in their bodies]] or if they are heavily damaged. Runs on power cells. Can be emagged for a heavy stun and some burn damage. |
| | }} |
| | |
| | {{anchor|Organ Transport Box}} |
| | {{Item |
| | |bgcolor1 = #CEFFF4 |
| | |bgcolor2 = #ADEDDF |
| | |name = Organ Transport Box |
| | |image = Organbox.gif |
| | |foundin = [[Vending machines|NanoMed Plus]] |
| | |usedfor = Transporting and preserving organs |
| | |description = Useful in emergencies where a stationary SmartFridge for organs is not present, or for the long-distance transport of organs. '''For the organ box to work, it requires chems for coolant'''. Accepted cooling chems are [[Guide_to_chemistry#Active_Pure_Chemicals|Ice]] and [[Guide_to_chemistry#Cryostylane|Cryostylane]]. |
| }} | | }} |
|
| |
|