Difference between revisions of "Air Alarm"

From Paradise Station Wiki
Jump to navigation Jump to search
(No difference)

Revision as of 07:07, 6 October 2017

An Air Alarm is the main method of control over the Cyberiad's Atmospheric System. They enable you to control the vents and scrubbers in rooms, as well as any other Atmospherics Equipment, in addition to accessing a multitude of options regarding Atmospherics duty.

There is an Air Alarm located in each individual room on the station, in addition to larger, open areas (such as Medbay or the Primary Hallways). Where exactly the Air Alarm is in the room does not matter; so long as it is withing the confines of the room, and the room itself is powered, it will allow you to control the room's atmospherics.

For more information about information governing the station's air supply, see the Guide to Atmospherics

Operating the Air Alarm

There are two ways of operating Air Alarms on the station:

Central Atmospherics Computer: By default, all Air Alarms can be remotely controlled via the use of the Central Atmospherics Computer, located in Atmospherics. Keep in mind, however, that if anyone shuts off Remote Access on the Air Alarm, it will no longer be accessible remotely unless there's an Atmospherics Emergency.

In Person: By default, all Air Alarms begin locked. Only the AI may directly interact with them, or someone using the Central Atmospherics Computer (see above). However, anyone with Engineering or Atmospherics access can simply click on an Air Alarm with their ID, unlocking it for use and granting them access to all of its functions.

Attention: Unlocking an Air Alarm means anyone can use it. Remember to lock it back when you're done.

The Air Alarm

This is what an Air Alarm will look like, in-game:

AirAlarm.png

It will be found along the walls, and provides a simple way of ascertaining whether there's a problem simply by looking at it: the green light will be blinking orange/red.

If the area the Air Alarm is in happens to be an Atmospherics Hazard Zone, then inspecting the Air Alarm via the Central Atmospherics Computer will allow you to see how serious it is, by the color of the triangle that indicates the Air Alarm:

Green: All good. No attention required.

Orange: Minor-Medium issue. Most likely a small dip in pressure, or a minor spill of toxic gas.

Red: Major issue. Usually signals massive depressurization/overpressurization, or very large spills of toxic gas. Fix immediately.

User Interface

Below is a sample UI of an Air Alarm:

AlarmUI.png

There are several parts to the Air Alarm interface. In order:

General Interface

Pressure: Current pressure in the room. Due to the nature of LINDA, this can vary slightly from tile to tile, but the number indicated tends to be a close approximation. If the number is orange, the room is still breathable, but barely. If the number is red, the room is not breathable.

Panic Syphon: Immediately begins syphoning all the air from the room. Will quickly drain the room down to near vacuum.

Oxygen: Percentage of Oxygen in the air. Should, optimally, be 20%. If the bar is orange, the percentage is not optimal, but breathable. If it's red, it's not breathable and needs to be adjusted.

Nitrogen: Percentage of Nitrogen in the air. Should, optimally, be 80%. If the bar is orange, the percentage is not optimal, but breathable. If it's red, it's not breathable and needs to be adjusted.

Carbon Dioxide: Percentage of Carbon Dioxide in the air. Is created by fires, or spills from Canisters. Will choke people who breathe it if in high enough concentrations. Should, optimally, be 0%. If it isn't, scrub it immediately.

Toxins: Percentage of Plasma in the air. Results from spills, or certain viruses. Is highly flammable, and breathing it causes Toxins damage. Should, optimally, be 0%. If it isn't, scrub it immediately.

Temperature: Current temperature of the room. Green numbers indicate perfectly livable conditions. Orange numbers indicate deviate, but still livable conditions. Red numbers indicate an environment that will cause Burn damage to anyone not wearing spaceproof gear.

Local Status: A quick summary of the immediate area.

Activate Alarm: Clicking this button will lock down the area's Hazard Shutters and send a notification to the AI and the Central Atmospherics Computer.

Remote Control: Can be used to grant/forbid access to Air Alarms via the Central Atmospherics Computer.

Thermostat: Allows you to change the temperature, from 10 Celsius to 40 Celsius.

Vents Interface

This interface allows you to control every vent in the room. Here is a sample UI:

Vents.png

Operating: Allows you to turn the vent On/Off, as well as choosing between Blowing or Syphoning. Blowing will keep the vent pumping out breathable air, while Syphoning will cause the vent to indiscriminately syphon all the air in the room.

Pressure Checks: Setting this option to Internal will force the vents to try and equalize the room's pressure with the pressure in the Distribution Loop. Since this is usually quite high, keep it set to External so the vents don't overpressurize the room.

External Pressure Target: Related to the above, the target pressure the Vents will try to match. The default value is perfect, so there's no need to change it.

Scrubbers Interface

This interface allows you to control every Vent in the room. Here is a sample UI:

Scrubbers.png

Operating: Allows you to turn the scrubber On/Off.

Type: Allows you to change the scrubber setting between Scrubbing and Syphoning. Syphoning will cause it to indiscriminately syphon all the air from the room, while Scrubbing will cause it to clear out specific gases.

Scrub Range: Allows you to choose between Normal/Extended range.

Filtering: Allows you to pick which gases get filtered by the scrubbers. Do not set it to filter N2 or O2 unless you want to actively sabotage the station.

Modes Interface

This interface allows you to select several preset vent/scrubber operating modes. Here is a sample UI, along with an explanation of each Mode:

Modes.png


Additional Information

  • Filtering - Default setting. Keeps room filtered of harmful gases while maintaining standard atmospheric pressure of 101.325 kPa;
  • Draught - Sets the scrubbers to siphon, while increasing vent output to 202.65 kPa;
  • Siphon - Sets the scrubbers to siphon while the vents are shut down;
  • Panic Siphon - Sets the scrubber to siphon and extends the range while the vents are shut down;
  • Cycle - Sets the scrubbers to siphon, then switches to 'Filtering' mode once the pressure reaches below 5 kPa;
  • Contaminated - Extends the scrubber's range allowing harmful gases to filter quickly;
  • Refill - Triples vent output to 303.975 kPa for fast re-pressurization;
  • Off - Vents and scrubbers are shut down

Thresholds Interface

This interface allows you to see the various pressure thresholds that are built into the Air Alarm. Here is a sample UI:

Thresholds.png

ATTENTION: DO NOT TAMPER WITH THESE VALUES UNLESS YOU WANT TO ACTIVELY SABOTAGE THE STATION