Difference between revisions of "Assemblies"
Sirryan2002 (talk | contribs) (→Assemblies: added caption) |
Sirryan2002 (talk | contribs) (→Devices: added radi) |
||
Line 60: | Line 60: | ||
!Igniter <br> [[File:Igniter.png]] {{Anchor|Igniter}} | !Igniter <br> [[File:Igniter.png]] {{Anchor|Igniter}} | ||
| Attempts to ignite whatever it is used on. When activated it will produce sparks(this will really only light plasma in the air on fire) | | Attempts to ignite whatever it is used on. When activated it will produce sparks(this will really only light plasma in the air on fire) | ||
|- | |||
! Radio <br> [[File:Station Bounced Radio.png]] | |||
| Will activate whenever it detects a signal(message) coming over a certain comms frequency. | |||
|} | |} | ||
Revision as of 19:29, 1 April 2021
Assemblies are devices that have been combined together to activate upon a certain condition being met and to either activate another device or send out a signal.
Signals
Many machines across the station use signals to communicate which each other. You may even be surprised to learn that some machines such as Air Injectors/Gas Computers, wall buttons, and even our comms all use signals to communicate and function. But how does all of that work?
Whenever an Assembly is activated and sends out a signal, it sends out that signal on a Frequency. Frequency comes in the form of numbers with odd decimals. For example, the frequency of a signal could be 101.3, 113.7, or 93.7. Since there are often multiple signals being sent on the same frequency there needs to be a way to differentiate the signals. This is where Codes come in. A code is just an accompanying number sent along with the signal that will further make the signal unique.
For example:
Signal 1: Frequency 101.3 Code: 4
Signal 2: Frequency 93.3 Code: 67
Anything on the same frequency and same code as the one described in Signal 1 will receive that signal and be activated, it will ignore all other signals.
Remote Signalers
Remote Signallers are devices from which you can send out signals from. You can set the frequency and code and you can choose to either manually activate it or attach it to another assembly to be activated once a condition is met. Additionally, you can set it to receive or send signals. As a receiver, if a signal is sent with the same frequency and code it is on, it will activate whatever it is attached to.
Attaching Remote Signallers to Machines
Whenever you open up the wire panel of an airlock, APC, air alarm, etc, there is a few options you have for each wire. You can cut or pulse it, but there is a third option called attach. If you click attach while holding a remote signaller, it will attach that signaller to that wire. Whenever the signaller is activated(as a receiver), it will pulse that wire like it was a multitool.
This can obviously accomplish a myriad of things, such as remotely locking doors or disabling APCs. You can have as many signallers on a machine as there are available wires, however, you cannot put more than one signaller on a single wire.
Devices
Type | Description |
---|---|
Timer |
When activated, it will wait a custom set time before detonating the bomb. |
Proximity Sensor |
When a mob steps within 1 tile in any direction of this trigger, it will activate. Use the assembly and set the timer for how long you want to give yourself to get away and press "not arming" so it will change to "arming". After this time has elapsed, any movement within one tile will trigger it. |
Health Sensor |
When the holder of the sensor hits crit or death (crit by default), it triggers. Ready to be attached by default. If you want to change it from detect crit (0 health) to detect death (-90 health), hit it with a multitool. |
Infrared Emitter |
When a mob steps in its line of sight, it will activate. Use the assembly to set the emitter's direction, state (on/off), and laser visibility. |
Remote Signaling Device |
When a signal with the same frequency is sent out (from anywhere), it receives it and activates. Use the assembly to set the frequency and the code. These should be different from the default to avoid anyone from just activating it(don't set your toxins bombs to default for the love of god). You can set it to either receive signals or send them out. |
Mouse Trap File:Mousetrap.gif |
Any person who opens the container containing the mousetrap will get instantly stunned and the mousetrap will activate. If a person walks over it on the ground it activates but will not stun them. Use the assembly to set the mousetrap, then place it inside any container or throw/drop it on the ground. |
Voice Analyzer |
Activates when a pre-recorded trigger word is said out loud within 7 tiles from the device. Use the assembly to start recording. Say the message out loud, then use it again to turn the recorder off and save the phrase. |
Noise Analyzer |
Activates when a sound is heard within 7 tiles from the device. Use the assembly and you can arm it. It will have a grace period(set by you) before it actually starts "listening" for noises. |
Igniter |
Attempts to ignite whatever it is used on. When activated it will produce sparks(this will really only light plasma in the air on fire) |
Radio |
Will activate whenever it detects a signal(message) coming over a certain comms frequency. |
Assemblies
Assemblies are devices that have been combined together. For example, you could attach a timer to a remote signaller to send out signals on 30-second pulses. You can combine up to three devices into an assembly.
In order to combine devices into an assembly, you must first set the conditions/settings of each device. Then you will need to apply a screwdriver to both devices. Now you will need to hold one of the devices in your hand and click on the other device to combine them. You will finalize the assembly by once again applying a screwdriver. You can still mess with the setting on both while it is completed, however, it should work at this point.
When one part of an assembly receives a signal, it will activate the other part of the assembly. For example, if someone trips an infrared laser on an infrared emitter/remote signaller assembly, the remote signaller will be activated. Additionally, if Remote Signaller 1 on a Remote Signaller/Remote Signaller assembly receives a signal on its frequency/code, it will activate Signaller 2 which will send out a signal on its set frequency/code.
Logic
For an assembly to actually do something, you will need to have an Input assembly and an Output assembly. Your Input assembly will be a device connected to a remote signaller, such device must activate when a condition is met and therefore send out a signal via the remote signaller. There must be another remote signaller on that frequency attached to your output device. This device could be attached to an airlock or even another assembly.
In the grand scheme of things, there are a lot of ways you can combine assemblies to accomplish different tasks using a variety of logical ciruits. It's really up to you to experiment to see what works.