Difference between revisions of "User:Jonttte"

From Paradise Station Wiki
Jump to navigation Jump to search
(Repairing WIP)
(updated icons, removed parts I'm not going to work on)
Line 35: Line 35:
! style='background-color:#ffc050' width:250px;                |Repairing
! style='background-color:#ffc050' width:250px;                |Repairing
|-
|-
![[File:Airlock.gif]]
![[File:Airlock_Damaged.gif]]
|Damaged
|Damaged
|The access panel is smoking. Examining shows that the airlock is slightly damaged, heavily damaged or falling apart.
|The access panel is smoking. Examining shows that the airlock is slightly damaged, heavily damaged or falling apart.
Line 41: Line 41:
* Apply welder on help intent
* Apply welder on help intent
|-
|-
![[File:Airlock.gif]]
![[File:Airlock Assembly.png]]
|Broken
|Broken
|The airlock has broken into an assembly.
|The airlock has broken into an assembly.
Line 49: Line 49:
* Apply screwdriver
* Apply screwdriver
|-
|-
![[File:Airlock.gif]]
![[File:Airlock Emagged.gif]]
|Emagged
|Emagged
|The airlock is stuck open. Examining shows that the access panel is smoking slightly.
|The airlock is stuck open. Examining shows that the access panel is smoking slightly.
Line 59: Line 59:
* Apply screwdriver
* Apply screwdriver
|-
|-
![[File:Airlock.gif]]
!
|Destroyed
|Destroyed
|The airlock is fully destroyed
|The airlock is fully destroyed
Line 74: Line 74:
! style='background-color:#ffc050' width:250px;                |Repairing
! style='background-color:#ffc050' width:250px;                |Repairing
|-
|-
![[File:Wall.png]]
![[File:Wall Damaged.png]]
|Damaged
|Damaged
|The wall is scorched. Examining shows that the wall is slightly, moderatly or heavily damaged
|The wall is scorched. Examining shows that the wall is slightly, moderatly or heavily damaged
Line 101: Line 101:
! style='background-color:#ffc050' width:250px;                |Repairing
! style='background-color:#ffc050' width:250px;                |Repairing
|-
|-
![[File:Wall.png]]
![[File:Reinforced Wall Damaged.png]]
|Damaged
|Damaged
|The reinforced wall is scorched. Examining shows that the reinforced wall is slightly, moderatly or heavily damaged
|The reinforced wall is scorched. Examining shows that the reinforced wall is slightly, moderatly or heavily damaged
Line 128: Line 128:
! style='background-color:#ffc050' width:250px;                |Repairing
! style='background-color:#ffc050' width:250px;                |Repairing
|-
|-
![[File:Window.png]]
![[File:Glass Wall Damaged.png]]
|Damaged
|Damaged
|The window is cracked. Examining shows that the window is slightly damaged, heavily damaged or falling apart.
|The window is cracked. Examining shows that the window is slightly damaged, heavily damaged or falling apart.
Line 134: Line 134:
* Apply welder on help intent
* Apply welder on help intent
|-
|-
![[File:Window.png]]
!
|Destroyed
|Destroyed
|The window is fully destroyed
|The window is fully destroyed
Line 150: Line 150:
! style='background-color:#ffc050' width:250px;                |Repairing
! style='background-color:#ffc050' width:250px;                |Repairing
|-
|-
![[File:Security Camera Console.gif]]
![[File:Console_Broken.png]]
|Damaged
|Damaged
|The computer console is blue-screened. Examining shows that the console is broken and non-functional
|The computer console is blue-screened. Examining shows that the console is broken and non-functional
Line 159: Line 159:
* Apply screwdriver
* Apply screwdriver
|-
|-
![[File:Security Camera Console.gif]]
![[File:Console_Frame_4.png]]
|Broken
|Broken
|The computer console has broken into a computer frame
|The computer console has broken into a computer frame
Line 167: Line 167:
* Apply screwdriver
* Apply screwdriver
|-
|-
![[File:Security Camera Console.gif]]
!
|Destroyed
|Destroyed
|The computer console is fully destroyed
|The computer console is fully destroyed
Line 182: Line 182:
! style='background-color:#ffc050' width:250px;                |Repairing
! style='background-color:#ffc050' width:250px;                |Repairing
|-
|-
![[File:Security Camera Console.gif]]
!
|Damaged
|Damaged
|Examining shows that the machine is slightly, moderatly or heavily damaged
|Examining shows that the machine is slightly, moderatly or heavily damaged
Line 192: Line 192:
* Apply screwdriver
* Apply screwdriver
|-
|-
![[File:Security Camera Console.gif]]
![[file:Machine_Frame_2.png]]
|Broken
|Broken
|The machine has broken into a machine frame
|The machine has broken into a machine frame
Line 200: Line 200:
* Apply screwdriver
* Apply screwdriver
|-
|-
![[File:Security Camera Console.gif]]
!
|Destroyed
|Destroyed
|The machine is fully destroyed
|The machine is fully destroyed
Line 207: Line 207:
|-
|-
|}</tab></tabs>
|}</tab></tabs>
=====Camera Networks=====
Camera monitors are all connected to certain networks when built. Cameras can be connected to networks during the screwdriving step of [[Guide to Construction#Security Camera| construction]].
See which monitor is connected to which network on the table below:
'''Note:'''
* The table only lists networks that newly built camera monitors connect to, camera monitors that spawn on the station might be connected to additional networks.
* The networks are case-sensitive and must be spelled out as shown.
{| class="wikitable mw-collapsible mw-collapsed" width="50%" style="background-color: #fffcec;"
|- style="font-weight: bold; text-align: center; background-color: #ffc050; color: white;"
| style="width: 150pt; center;" | Camera Console
| style="width: 150pt; center;" | Networks
|-
! Security Camera Console
[[File:Security Camera Console.gif]]
|
* SS13
* Mining Outpost
|-
! Entertainment Monitor
|
* news
|-
! Wooden TV
|
* SS13
|-
! Outpost Camera Monitor
|
* Mining Outpost
|-
! Engineering Camera Monitor
|
* Power Alarms
* Atmosphere Alarms
* Fire Alarms
|-
! Research Monitor
|
* TestChamber
|-
! Research Director Monitor
|
* Research
* Research Outpost
* RD
* MiniSat
|-
! Prison Monitor
|
* Prison
|-
! Interrogation Monitor
|
* Interrogation
|-
! MiniSat Monitor
|
* Minisat
* tcomm
|-
! AI Upload Monitor
|
* AIUpload
|-
! Vault Monitor
|
* vault
|-
! Turbine Vent Monitor
|
* Turbine
|-
! Engine Camera Monitor
|
* engine
|-
|}
<br>
<br>
<br>
===Hull Breaches===
[[File:Hull Breach.png|right|frame|A Hull Breach]]
The first thing you should do in the case of a hull breach is seal off the breached area from the general public, in order to prevent injuries and further atmospheric losses. Have an Atmos tech use a Holofan Projector to seal off areas, and use an Engineering Barrier Projector to keep people from entering spaced areas. If holofans aren't available, consider using inflatable barriers to do the job instead.
If there are missing floors, use metal rods to create lattices, and then use floor tiles on the lattice to create floor plating. Otherwise, replace the walls and windows as needed.
====Restoring Atmospherics====
This is a job for your local [[Atmospheric Technician|Atmos Wizards]] but if they're not available you'll need to help out. Ensure that all of the supply pipes (blue pipes) are wrenched down and all the unary vents are also wrenched down. If the Air Alarm is intact then air should flow into the room and pressurize it.
If this is an area without vents, then use Oxygen grenades or a portable air injector with an O2 tank to finish the job.
For more information check the [[Guide to Atmospherics]].
<br>
<br>
<br>
===Widespread Destruction===
[[File:Large Scale Destruction.png|right|400px|frame|The results of a Syndicate Bomb]]
A max cap will inevitably be detonated on the station or the SM might decide to have a meltdown. This often leaves sections of the entire station destroyed and rendered unusable. Sometimes you can fix it, sometimes you cant. Engineering will have to work as a team to fix this issue.
While there's no one way to go about fixing these issues here are a few tips
* Focus on sealing breaches as quickly as possible first. Mesons are useful for seeing breaches through walls.
* Make sure to establish a pressurized escape route for those who are isolated because of the damage.
* Prioritize rebuilding parts of the station in this order: [[Escape]], Central Primary Hallway/Starboard Primary Hallways, [[Arrivals]], [[Medbay]], other departments, everything else.
If you cannot rebuild an area, consider just walling it off and having the CE condemn the area. Doing so will bar anyone from going into it.

Revision as of 13:43, 19 July 2024

HI!! Welcome to my userpage!

I'm a mentor on paradise station. Though, when I play SS13 I tend to split my time fairly evenly between Paradise Station and CM-SS13.

Good luck on your wiki adventures, traveler. Always remember: YOU are BASED!

Epic Userbox modified from LordisMangis's templates:

Generic security.png This user knows the difference between beauty and trash Generic assistant.png



Very Epic ↑




↓ Wip in progress below ↓


Full page: Guide to Engineering

Fixing Stuff

Fixing good

Icon Type Description Repairing
Airlock Damaged.gif Damaged The access panel is smoking. Examining shows that the airlock is slightly damaged, heavily damaged or falling apart.
  • Apply welder on help intent
Airlock Assembly.png Broken The airlock has broken into an assembly.
  • Use airlock electronics in-hand to set access
  • Apply airlock electronics
  • Apply screwdriver
Airlock Emagged.gif Emagged The airlock is stuck open. Examining shows that the access panel is smoking slightly.
  • Apply screwdriver
  • Apply crowbar
  • Use airlock electronics in-hand to set access
  • Apply airlock electronics
  • Apply screwdriver
Destroyed The airlock is fully destroyed
Icon Type Description Repairing
Wall Damaged.png Damaged The wall is scorched. Examining shows that the wall is slightly, moderatly or heavily damaged
  • Apply welder on help intent
Wall.png Broken The wall has broken into a girder
  • Apply 2 metal
Wall.png Destroyed The wall is fully destroyed
Icon Type Description Repairing
Reinforced Wall Damaged.png Damaged The reinforced wall is scorched. Examining shows that the reinforced wall is slightly, moderatly or heavily damaged
  • Apply welder on help intent
Wall.png Broken The reinforced wall has broken into a reinforced girder
  • Apply 2 plasteel
Wall.png Destroyed The reinforced wall is fully destroyed
Icon Type Description Repairing
Glass Wall Damaged.png Damaged The window is cracked. Examining shows that the window is slightly damaged, heavily damaged or falling apart.
  • Apply welder on help intent
Destroyed The window is fully destroyed
Icon Type Description Repairing
Console Broken.png Damaged The computer console is blue-screened. Examining shows that the console is broken and non-functional
  • Apply screwdriver
  • (Optional) Apply welder on the glass shards
  • Apply 2 glass
  • Apply screwdriver
Console Frame 4.png Broken The computer console has broken into a computer frame
  • (Optional) Apply welder on the glass shards
  • Apply 2 glass
  • Apply screwdriver
Destroyed The computer console is fully destroyed
Icon Type Description Repairing
Damaged Examining shows that the machine is slightly, moderatly or heavily damaged
  • Apply screwdriver
  • Apply crowbar
  • Add the circuit board
  • Add the components
  • Apply screwdriver
Machine Frame 2.png Broken The machine has broken into a machine frame
  • Add the circuit board
  • Add the components
  • Apply screwdriver
Destroyed The machine is fully destroyed